Rockwell Ethernet/IP Module : Understanding Ethernet Features And Their Practical Use

                                        

                                        Studio-5000-RPI, Rockwell-Ethernet-Unicast-Vs-Multicast

14th October, 2026.

In this post, we will see the concept of the features and diagnostics generally used in a Rockwell Ethernet/IP module in offline mode.

Ethernet/IP communication modules like AENT and EN2TR in Rockwell Automation systems establish communication between PLCs, remote I/O, HMIs, drives, and other devices. In addition to basic communication functions, such modules implement a few Ethernet-specific settings that define communication rules, network configuration and diagnostic tools, and motion-related instructions. Knowledge of these settings and diagnostics can help an automation engineer to configure the network correctly and troubleshoot communication problems. In this article, we will look at the significant Ethernet settings and status on the Rockwell EtherNet/IP modules and try to understand how these settings relate to their respective purposes. We will also use some practical examples of how these settings can be applied in real automation tasks. The settings we discuss here are related to offline ones and not online.

What is the setting of 10/100 Mbps?

The speed of the Ethernet determines the rate at which it can transmit the data. Thus, a Rockwell EtherNet/IP module with 10 / 100 Mbps option can operate at 10 Mbps or 100 Mbps depending on the setting or connected device. The term “Mbps” stands for “megabits per second.” For most automation applications, a 100 Mbps speed rate is preferred because it is usually faster and facilitates more data exchange than 10 Mbps. Some modules have an auto-negotiation feature that allows them to decide the speed and duplex settings at which they will operate. When configuring such a module, it is important to ensure that the speed and duplex setting are compatible on both ends of the link.

What is time synchronization and motion synchronization in Rockwell Ethernet/IP module?

The Time Sync Connection setting has two options: None and Time Sync & Motion. This setting determines if the Ethernet module supports the applicable time-synchronization and motion-related connections.

Time synchronization is the synchronization of clocks of compatible devices. For example, if a PLC and a servo drive record a fault, the synchronized clocks help the engineers compare the timestamps and identify the cause. Rockwell systems can use CIP Sync for this purpose.

Motion synchronization involves the coordination of servo movements. For example, in a packaging machine, one servo feeds the film while another operates the cutter. The motion controller coordinates their movements so that the cut occurs at the correct position. Precise time synchronization can support this coordination, but it does not automatically synchronize the motors.

Practical example: In a machine with multiple servo axes, make sure to select Time Sync & Motion because the application requires the supported CIP Sync and motion-related capabilities. The controller, drives, and configuration should also support these functions.

We will answer some general questions which are asked by many engineers for this topic.

A. When to select time sync and motion option in AENT/EN2TR module? 

Think of Time Sync & Motion as enabling the Ethernet module to support two functions:

1. Time synchronization: Imagine two PLCs recording a fault. If their clocks are different, one PLC might record the fault at 10:05:02 while the other records it at 10:05:05. This makes troubleshooting confusing. CIP Sync helps compatible devices to synchronize their clocks so events can be coordinated with accurate time stamps.

2. Motion control: In applications using servo drives and motion controllers, accurate timing helps coordinate the devices' movement. Multiple servo axes may need to move at just the right time.

In simple terms: Select Time Sync & Motion when the application requires those capabilities and the module support them. It does not mean that the module itself automatically performs motion control.

B. What is the difference between time synchronization and motion synchronization in Ethernet/IP module? 

Motion synchronization: There are instances where multiple servo motors must be coordinated (in terms of movement) to perform a machine operation correctly. For example, in a packaging machine, one servo may feed the packing film, and another operates the cutting mechanism. Their movements must be coordinated so that the cut occurs at the correct position. The Time Sync & Motion option supports the time-synchronization capabilities required by compatible Rockwell motion-control systems, to help devices coordinate time-critical operations over EtherNet/IP. However, only selecting this option does not synchronize the motors or configure motion control. The controller, servo drives, network configuration, and motion application must also support and be configured for those functions. It primarily means to synchronize time, not physically synchronize the motion of the motors.

In Rockwell systems, Time Sync & Motion refers to support time synchronization and motion-related communication.

For example, imagine two servo drives that must move together. The controller must coordinate their commands just right. Synchronized clocks help the devices to execute time-critical operations at the intended time, to support coordinated motion. However, the actual synchronization (of the motors' movement) is handled by the motion controller, servo drives, and configured motion-control system. The Ethernet module provides the required communication capabilities; selecting this option does not automatically synchronize the motors.

In simple terms: Time synchronization aligns device clocks, and motion synchronization coordinates motor movement, using the motion-control system.

Let's take a practical example of an automatic packaging machine with two servo motors and a Rockwell PLC. This will help to distinguish time synchronization from motion synchronization.

 1. Time synchronization - syncing clocks

Imagine the machine has a PLC, Servo Drive 1 and Servo Drive 2. Each device has an internal clock. Suppose a fault occurs during operation. The PLC records it at 10:00:05.100, while a drive records its event at 10:00:05.300. If their clocks are not synchronized, it may be confusing to find out which occurred first. With time synchronization, such as CIP Sync, compatible devices have aligned clocks based on a common time reference. The timestamps can be accurate compared to troubleshooting the machine. Think of it as: Synchronizing watches worn by three people. All three watches are shown at the same time.

 2. Motion synchronization - coordinating movement

Now here's what the two servo motors do:

Servo Motor 1: Feeds packaging film forward.

Servo Motor 2: Operates the cutting mechanism.

Suppose the film must be advanced 200 mm before the cutter can cut it. The cutter must operate at precisely the correct position (in relation to the film). If the two motors operate independently without proper coordination, the cut may occur too early or too late. A Rockwell motion controller can coordinate the two servo axes using configured motion instructions and appropriate motion-control mechanisms. The motors will follow the required position, speed and timing relationships. Think of it as: Two dancers performing coordinated steps. Their movements must match the choreography, not merely their clocks.

 3. How are time synchronization and motion synchronization related?

Time synchronization

a.      PLC clock

b.      Drive clocks

Purpose: Devices share a common time reference.

Motion synchronization

a.     Film-feed motor

b.     Cutter motor

Purpose: Motor movements follow the required relationship.

The important distinction is that synchronized clocks do not automatically synchronize motor movements. Time synchronization can give a common, accurate time reference that an appropriate motion-control system can use, but the controller and drives must still be configured to coordinate the axes.

The Time Sync & Motion option indicates support for the applicable time-synchronization and motion-related capabilities (but the actual functions depend on the module model and firmware).

C. Does motion synchronization only mean to pass motion parameters through Ethernet? 

Motion synchronization does not simply mean that parameters are transferred simultaneously through Ethernet. Consider two servo drives in a packaging machine: The PLC sends motion commands (such as position, speed, or movement instructions) to the drives over EtherNet/IP. The motion-control system coordinates when the drives should execute their commands. The drives control their motors so that their movements follow the required relationship.

Time synchronization (when required) helps to provide a common, precise time reference. However, motion coordination also depends on the controller, drive capabilities, and motion-control mechanism.

In simple terms: Ethernet transfers the data, and the motion-control system coordinates the movement. The Time Sync & Motion setting enables the applicable communication capabilities; it does not, by itself, make all parameters transfer simultaneously.

What is request packet interval or RPI in Rockwell Ethernet/IP module?

The Requested Packet Interval (RPI) is the time between data transmittances from the PLC to the EtherNet/IP remote device or from the remote device to the PLC. This time interval is set in milliseconds (ms). If the RPI is 10 ms, the connection will request an update every 10 ms. A shorter interval (lower number) increases the amount of data that must be processed by the controller and on the network and makes the connection more responsive. A larger interval (higher number) reduces the amount of data but reduces the connection’s responsiveness. The RPI value should be set considering the requirements of the connected device and the network.

What is Unicast and Multicast in Rockwell Ethernet/IP module?

The Use Unicast Connection option defines whether EtherNet/IP traffic is unicast- or multicast-sent to a specific receiving device. For instance, if your Rockwell PLC communicates with a remote I/O adapter, by enabling the Use Unicast Connection, you will send the I/O data directly to the remote I/O adapter. At the same time, by disabling it, you will send this data to all devices in your network that have joined the multicast group. Overall, using unicast connections is better for larger networks because it reduces traffic. It can be utilized if supported by your controller, communication module, and remote device. In most cases, it is a recommended option for point-to-point I/O communication.

A normal Ethernet switch can also be used since it can forward multicast traffic, so a managed switch is not mandatory. The difference is that a managed switch can intelligently handle this traffic. This is done via the IGMP snooping function, which allows the switch to examine the IGMP messages sent by the host devices and determine which of its ports should receive them. In other words, if one device sends I/O data to the multicast address, the IGMP snooping-enabled switch will only forward this traffic to the ports that have requested to join the multicast group instead of all ports.

This way, it can optimize the traffic flow, especially for larger Ethernet networks. For example, when your PLC sends I/O data to the remote I/O adapter(s) using a multicast connection, ideally, only the adapter(s) will receive this data since they have joined the multicast group. However, if you have a normal (unmanaged) switch, this data will also be sent to all other ports and, thus, all devices. This can significantly increase the traffic since, in most cases, these devices will not need this data. For most smaller networks, a normal Ethernet switch will be sufficient. However, for larger EtherNet/IP networks using I/O multicast connections, it is better to use a managed switch with the IGMP snooping feature enabled.

I have covered the general theory on understanding the settings in AENT or EN2TR communication module in offline mode. I have also not attempted to cover all the topics related to it, as it can vary from case to case. Once you are familiar with this type of technology, you can easily troubleshoot any issues related to it.

Thank you for reading the post. I hope you liked it and will find a new way in this type of technology.




Written by Viral Nagda, Industrial Automation Engineer with 12+ years of experience…



Comments

  1. The packaging-machine example makes the difference between synchronizing clocks and coordinating motion much easier to follow. It is particularly helpful that selecting Time Sync & Motion is distinguished from configuring the controller and drives to coordinate the axes. The discussion of RPI also connects a familiar setting to its practical trade-off between response time and network load. A clear explanation that gives the settings a purpose beyond simply naming them.

    ReplyDelete

Post a Comment

If you have any queries, please let me know